PUBLISHED: Open Reduction and Internal Fixation of Mandibular Body and Parasymphyseal Fractures with Maxillomandibular Fixation and Broken Tooth Extraction

Open Reduction and Internal Fixation of Mandibular Body and Parasymphyseal Fractures with Maxillomandibular Fixation and Broken Tooth Extraction
Derek Sheen, MD1Cheryl Yu, MD2Sarah Debs, MD2Peter Kwak, MD2Nima Vahidi, MD3Daniel Hawkins, DDS2Thomas Lee, MD, FACS2
1University of Texas Southwestern Medical Center
2Virginia Commonwealth University Medical Center
3Upstate Medical Center

This is a case discussing a 21-year-old male who suffered from both non-comminuted mandibular parasymphyseal and body fractures as a result of a motor vehicle accident, requiring open reduction internal fixation (ORIF) without postoperative maxillomandibular fixation (MMF). The fracture was complicated by a broken tooth root, which required extraction.

After intraoperative MMF, ORIF was performed. The parasymphyseal fracture was plated using two locking four-hole 2-mm thick miniplates utilizing two locking screws on either side of the fracture with one plate along the alveolar surface (monocortical screw) and one along the basal surface (bicortical screw). For the right body fracture, a three-dimensional locking ladder plate was used via a transbuccal trocar approach for additional exposure needed for proper screw placement. Once the hardware was secured, the patient was taken out of MMF and restoration of premorbid occlusion was confirmed. Lastly, watertight mucosal closure was performed using absorbable sutures and Dermabond (cyanoacrylate adhesive).